Filter Results By:

Products

Applications

Manufacturers

Showing results: 1321 - 1335 of 1604 items found.

  • Multi-Channel Digital Power Meters

    66203/66204 - Chroma Systems Solutions, Inc.

    Voltage Range :15/30/60/150/300/600 VrmsCurrent Range :0.005/0.02/0.05/0.2/0.5/2/5/20 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bits Analog/Digital convertersHalf rack size, 4 input modules design (66204)Support different wiring configuration power measurement (1P2W/1P3W/3P3W/3P4W)Support external shunt and CT for higher current measurement application5 mA minimum current range & 0.1mW power resolutionMeets ENERGY STAR / IEC 62301 /ErP measurement requirementsAccumulated energy methods for unstable power measurementUser-define criteria provides automatic PASS/FAIL indicationsDual current shunt design provides high accuracy over a wide current rangeTHD and user-specify order distortion measurementInrush current and energy measurementVoltage/ Current harmonics measurement up to 50 orders

  • FD-11601, 8-Channel, ±10 V Powered-Sensor Voltage Input Device for FieldDAQ

    786374-01 - NI

    The FD-11601 measures up to eight channels with a voltage input range of ±10 V. Each input channel supports TEDS and provides 24 V DC to power external-powered sensors without additional power supplies. The FD-11601 features 24-bit resolution, simultaneous sample rates up to 100 kS/s/ch, and channel-to-channel isolation. It is IP65/IP67 rated to be dust-tight and water-submersible, operates in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11601 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11601 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11601 is ideal for test cell and outdoor environments.

  • Hygro Thermometer

    KM 918 A - Kusam Electrical Industries Limited

    * Temperature range : -10 ~ 60oC / (14 ~ 140oF)* Temperature accuracy : ± 1o C / (± 1.8oF)* Temperature resolution: 0.1 oC /oF* Humidity range: 20% RH ~ 95 % RH* Humidity resolution: 1 % RH* Humidity Accuracy: 8 % RH* Clock, temperature and humidity display * Room and outside temperature* Room Humidity display* Maximum or minimum memorization function * Alarm clock function at a desired hour.* Power : 1.5V DC AAA battery

  • PCI Express A/d Board

    AD14-500x4-8GB-K7US - Ultraview Corporation

    The AD14-500x4-8GB-K7US is a high performance wideband 4-channel 14-bit data single PCIe Gen3 board, that can continuously digitize four wideband signals, with four high linearity A/Ds.Designed for demanding military, medical, scientific, industrial, communications, safety and electrical power utility applications, these boards have a wideband noise figure of 10dB and 1 dB peak-to-peak ripple over the DC to 250MHz frequency spectrum (2dB p-p over DC-500MHz).

  • Seismic Signal Conditioners

    Metrix

    Seismic signal conditioners are designed to accept an input from (and provide power to) a seismic sensor. They convert the signal to a proportional 4-20mA DC signal that can be used as an input to process control instrumentation such as a PLC or DCS.  They provide additional convenience features such as optional displays, BNC connectors for access to the dynamic sensor signal, and bandpass filtering.  Metrix offers seismic signal conditioners that can accept either acceleration or velocity sensors, and are available with or without an integral display.

  • Adjustable Range Reflective Photoelectric Sensor

    EQ-500 - Panasonic Industrial Devices Sales Company of America

    The EQ-500 Series Adjustable Range Reflective Photoelectric Sensor is a multi-voltage compact Reflective Photoelectric Sensor that can function with 24 to 240 V.AC and 12 to 240 V.DC, to operate with any power supply around the world. Background and foreground suppression (DC Types) and a long sensing range of up to 2.5m is a key characteristic of the EQ-500 Sensor. With an IP67 rating, the EQ-500 can be used in harsh environments prone to water or dust making stable sensing possible.

  • Medium- to High-Power DC Load ISSRs

    Part No. S75DC150 - Teledyne Defense Electronics Relays & Coax Switch

    Your product description goes here.Series S75 relays switch medium- to high-power DC loads. These devices feature the latest-generation MOSFET technology as well as an innovative isolated driver to ensure fast power turn on and off. The relays feature triggered control input to avoid linear control risks and fast switching times. The relays also offer an LED for status.​Available options include:S75DC150 150A, 0-42 Vdc Load; 4.5-32 Vdc Control​

  • Dynamic Micro Ohm Meter

    PRIME 200 - EUROSMC, S.A.

    It is the only micro ohm meter in the market that integrates both the contact resistance and the dynamic resistance measurement (DRM) for cost-efficient condition evaluation of contacts in SF6 and vacuum type circuit breakers; PRIME is a high current micro-ohmmeter that provides true pure DC with smart control up to 200 A, a wide measurement range with high power, dual ground testing process, thermal printer, touch display, pre-defined test modes and automatic reporting.

  • Dynamic Micro Ohm Meter

    PRIME 600 - EUROSMC, S.A.

    It is the only micro ohm meter in the market that integrates both the contact resistance and the dynamic resistance measurement (DRM) for cost-efficient condition evaluation of contacts in SF6 and vacuum type circuit breakers; PRIME is a high current micro-ohmmeter that provides true pure DC with smart control up to 600 A, a wide measurement range with high power, dual ground testing process, thermal printer, touch display, pre-defined test modes and automatic reporting.

  • 48-Ch Switching

    YAV91074 - 6TL Engineering

    The YAV90074 module contents 48 SPDT Relays independent. Each relays PCB contact track is shielded individually in order to handle very low voltage signals and audio signals with extremely low crosstalk. The build-in power supply includes two extra filters to reduce the DC voltage ripple to the relay coils; the control tracks have been drawn in quadrature with signal ones, reducing the inductive coupling produced by the transient current.

  • DC Alignment

    SEP/SIP - Nihon Denji Sokki Co., Ltd

    There are analog phase control type DC power supply type and digital control type inverter energy saving type. We provide the most suitable equipment according to the current capacity and cycle time.If the "start command" is executed from the existing molding equipment, each mode of "alignment-pause-demagnetization" is continuously operated by the program inside the instrument. It is also possible to share an emergency stop signal and output an output current abnormality signal.

  • Low Noise Amplifiers

    Macom Technology Solutions Holdings Inc.

    MACOM low noise amplifier MMICs cover a frequencies from DC to 86 GHz operation for a wide range of applications, including network infrastructure, radar and communication systems. MACOMs portfolio of low noise amplifiers offer a broad array of noise figures, input IP3, and input power in bare die and a variety of package types. Offerings include wideband distributed topologies and self or actively biased configurations tailored to system design needs.

  • Circuit Breaker Tester

    GDGK-303 - Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd

    1) Closing and opening time measurement of 12 channels2) Max difference of closing or opening time measurement of three phases3) Bounce time and frequency measurement of breaker closing4) Circuit breaker closing and opening speed measurement5) Travel-time, Coil current-time curve of circuit breaker operation measurement6) Clearance of circuit breaker measurement7) Variable DC circuit breaker operation power supply8) Print test results by internal micro printers

  • Photovoltaic and Electrical Installation Testers

    3108 - Metrel d.d.

    MI 3108 EurotestPV is a combined photovoltaic tester and electrical installations safety tester. It enables complete testing of electrical installations according to EN 61557 standards and in addition performs all necessary tests required on single-phase photovoltaic (PV) installations. This includes all of the tests as required by EN 62446, but also includes I - U characteristic, Calculation of STC values as required by EN 61829 and power measurements on Inverter’s DC and AC sides.

  • Power Quality Analyzers

    APQM-702/APQM-703 - Amperis sl

    *It can be powered from the L phase.*It is intended for use in virtually all types of networks from 64 V to 760 V directly, with special consideration for measurements on low-voltage poles, due to its ease of connection.*It has an independent power supply and is therefore particularly suitable for measurements outside of voltage transformers. It can also be adapted for measurements on DC voltage systems.*Real-time remote configuration and data transfer (GPRS) using a built-in GSM modem

Get Help